Installing water level controls
The water level control unit should be mounted in
the fountain's dry pump chamber or control room (or a suitable dry
location)
The water level sensor should be fixed to the pool wall,
the height determines the level at which the water inlet valve will
operate.
The sensor comes with 10m of cable and should exit the
pool via a suitable gland. The cable is then connected to the level
control panel.
The control panel requires a 230v ac supply with means
of local isolation, a switched fused connection unit fitted
with 5A fuse fitted is suitable)
A cable (not supplied) should be connected from the
control panel to the water inlet valve. The water inlet valve is 24 v
Water and mains should then be switched on and the
controls adjusted accordingly.